HIGH PASS-RATE RELIABLE FIRE-INSPECTOR-II EXAM SIMULATIONS, FIRE-INSPECTOR-II TEST TORRENT

High Pass-Rate Reliable Fire-Inspector-II Exam Simulations, Fire-Inspector-II Test Torrent

High Pass-Rate Reliable Fire-Inspector-II Exam Simulations, Fire-Inspector-II Test Torrent

Blog Article

Tags: Reliable Fire-Inspector-II Exam Simulations, Fire-Inspector-II Test Torrent, Fire-Inspector-II Reliable Test Price, Exam Fire-Inspector-II Learning, Valid Fire-Inspector-II Dumps Demo

We've always put quality of our Fire-Inspector-II guide dumps on top priority. Each Fire-Inspector-II learning engine will go through strict inspection from many aspects such as the operation, compatibility test and so on. The quality inspection process is completely strict. The most professional experts of our company will check the Fire-Inspector-II study quiz and deal with the wrong parts. That is why we can survive in the market now. Our company is dedicated to carrying out the best quality Fire-Inspector-II study prep for you.

This is where your Fire-Inspector-II exam prep really takes off, in the testing your knowledge and ability to quickly come up with answers in the Fire-Inspector-II online tests. Using Fire-Inspector-II practice exams is an excellent way to increase response time and queue certain answers to common issues. Get Fire-Inspector-II ebooks from Exams4Collection which contain real Fire-Inspector-II exam questions and answers. You will pass your Fire-Inspector-II exam on the first attempt using only Exams4Collection's Fire-Inspector-II excellent preparation tools and tutorials

>> Reliable Fire-Inspector-II Exam Simulations <<

Fire-Inspector-II Test Torrent & Fire-Inspector-II Reliable Test Price

There are a lot of leading experts and professors in different field in our company. The first duty of these leading experts and professors is to compile the Fire-Inspector-II exam questions. In order to meet the needs of all customers, the team of the experts in our company has done the research of the Fire-Inspector-II Study Materials in the past years. And they have considered every detail of the Fire-Inspector-II practice braindumps to be perfect. That is why our Fire-Inspector-II learning guide enjoys the best quality in the market!

International Code Council 67 - Fire Inspector II Exam Sample Questions (Q72-Q77):

NEW QUESTION # 72
One or more approved fire extinguishers must be located within __ ft. of hot work locations.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
Fire Extinguisher Requirements for Hot Work Locations
According to the International Fire Code (IFC) 2021, Section 3504.2.6, one or more approved fire extinguishers must be located within 30 feet of hot work locations.
Hot work includes welding, cutting, grinding, brazing, or any operation that generates heat, sparks, or flames.
2. Why 30 Feet is the Correct Answer
Hot work presents a high fire risk, and quick access to fire extinguishers is crucial for immediate response.
The 30-foot requirement ensures that extinguishers are readily accessible without obstructing the work area.
3. Verification of Other Options
Option A (20 feet) - Incorrect, as the IFC mandates a 30-foot minimum distance.
Option C (40 feet) - Incorrect, as this exceeds the maximum distance allowed under the fire code.
Option D (50 feet) - Incorrect, as fire extinguishers must be closer to provide effective fire suppression.
Reference Sources:
International Fire Code (IFC) 2021 - Section 3504.2.6 (Fire Extinguishers for Hot Work) NFPA 51B: Standard for Fire Prevention During Welding, Cutting, and Other Hot Work ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: B. 30 feet. #


NEW QUESTION # 73
In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

Explanation:
Exit Announcements in Motion Picture Theaters
According to the International Fire Code (IFC) 2021, Section 403.9.1.2, motion picture theaters must provide an audible announcement informing occupants of exit locations no more than 5 minutes prior to the start of each program.
This requirement ensures that audience members are aware of exit locations in case of an emergency, enhancing fire safety in crowded venues.
2. Verification of Other Options
Option B (10 minutes) - Exceeds the IFC maximum timeframe. Incorrect.
Option C (20 minutes) - Not specified in the IFC as a valid timeframe. Incorrect.
Option D (30 minutes) - Far beyond the required timeframe and would likely be ineffective. Incorrect.
Reference Sources:
International Fire Code (IFC) 2021 - Section 403.9.1.2 (Theater Exit Announcements) NFPA 101: Life Safety Code (Theater Occupancy Requirements) ICC Fire Inspector II Study Guide (2021)


NEW QUESTION # 74
Compressed natural gas (CNG) motor vehicle fuel-dispensing equipment may be installed in which of the following locations?

  • A. 15 ft. from a public street.
  • B. 40 ft. from trolley wires.
  • C. 5 ft. from an undeveloped property line.
  • D. 20 ft. from a railroad track.

Answer: D

Explanation:
Compressed Natural Gas (CNG) motor vehicle fuel-dispensing equipment installation requirements are outlined in 2021 International Fire Code (IFC) Section 2208 - Compressed Natural Gas Motor Fuel- Dispensing Facilities.
IFC 2021, Section 2208.3 - Equipment Location and Protection:
Requires that CNG dispensing equipment be installed at least:
10 feet from property lines
20 feet from public streets, highways, sidewalks, or railroads
10 feet from buildings or structures
Why Other Options Are Incorrect?
A: 40 ft. from trolley wires.
The IFC does not specify a 40-ft requirement for trolley wires in relation to CNG fuel-dispensing equipment.
B: 15 ft. from a public street.
Incorrect because IFC 2208.3 states that the minimum required distance from a public street is 20 feet, not 15 feet.
D: 5 ft. from an undeveloped property line.
Incorrect, as the minimum clearance from any property line is 10 feet, not 5 feet.


NEW QUESTION # 75
Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.
How long must records related to this decision be maintained by the code official?

  • A. Three years
  • B. Five years
  • C. Until the building is sold
  • D. For as long as the building and the condition exist

Answer: D

Explanation:
Retention of Fire Code-Related Records
According to the International Fire Code (IFC) 2021, Section 104.6, records related to code enforcement decisions, including modifications or substitutions (such as a sprinkler system replacing a second exit), must be retained for as long as the building and the condition exist.
This ensures that future inspections, property owners, and authorities can verify past decisions and compliance history.
2. Why the Records Must Be Retained Permanently
Modifications that impact life safety (such as exit requirements) must remain on record for the lifetime of the building to ensure ongoing compliance and safety.
If the condition (sprinkler substitution for an exit) still exists, any future inspector or building official must be able to verify the original approval and rationale.
3. Verification of Other Options
Option A (Five years) - Incorrect, as fire code modifications must remain on record permanently if they affect egress or fire protection systems.
Option B (Three years) - Incorrect, as this timeframe applies to temporary inspection reports, not major code modifications.
Option C (Until the building is sold) - Incorrect, as ownership changes do not affect the need for record retention on fire safety decisions.
Reference Sources:
International Fire Code (IFC) 2021 - Section 104.6 (Fire Code Record Retention Requirements) NFPA 1: Fire Code (Retention of Code-Related Decisions) ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: D. For as long as the building and the condition exist. #


NEW QUESTION # 76
Pressure tests for organic coating process piping shall be conducted for a minimum of:

  • A. 1 hour
  • B. 30 minutes
  • C. 2 hours
  • D. 45 minutes

Answer: A

Explanation:
Pressure tests for organic coating process piping are required to ensure system integrity and prevent leaks, which could lead to fire or explosion hazards. The minimum required duration for these pressure tests is 1 hour.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 1504.6.3 (Pressure Testing for Organic Coating Process Piping) IFC 1504.6.3 mandates that all process piping associated with organic coating operations must undergo a pressure test for at least 1 hour. This ensures that the pipes can handle operational pressures without failure.
2. NFPA 33 - Standard for Spray Application Using Flammable or Combustible Materials (2021 Edition) NFPA 33, Section 14.2.6 confirms that process piping must be pressure-tested for no less than 1 hour to verify its safety and reliability.
Detailed Explanation of Answer Choices:
Option A (Incorrect): 30 minutes is insufficient for proper pressure testing.
Option B (Incorrect): 45 minutes is still below the 1-hour minimum requirement.
Option C (Correct): 1 hour is the correct minimum test duration as required by IFC 1504.6.3 and NFPA 33.
Option D (Incorrect): 2 hours is longer than required, but the minimum requirement is 1 hour.
Thus, the correct and verified answer is: C. 1 hour.


NEW QUESTION # 77
......

Just the same as the free demo, we have provided three kinds of versions of our International Code Council Fire-Inspector-II preparation exam, among which the PDF version is the most popular one. It is understandable that many people give their priority to use paper-based Fire-Inspector-II Materials rather than learning on computers, and it is quite clear that the PDF version is convenient for our customers to read and print the contents in our 67 - Fire Inspector II Exam Fire-Inspector-II study guide.

Fire-Inspector-II Test Torrent: https://www.exams4collection.com/Fire-Inspector-II-latest-braindumps.html

International Code Council Reliable Fire-Inspector-II Exam Simulations Once you pay we have one year service warranty for exam subject you pay, If you have achieved credential such as International Code Council Fire-Inspector-II Test Torrent then it means a bright future is waiting for you, There are a number of distinctions of our Fire-Inspector-II exam questions that make it superior to those offered in the market, You can take the International Code Council Fire-Inspector-II training materials and pass it without any difficulty.

Why do thousands of buyers choose our Fire-Inspector-II exam dumps every year, Get used to it, because this is standard operating procedure for Windows XP Media Center Edition–based PCs.

Once you pay we have one year service warranty for exam subject Fire-Inspector-II you pay, If you have achieved credential such as International Code Council then it means a bright future is waiting for you.

Professional Reliable Fire-Inspector-II Exam Simulations, Ensure to pass the Fire-Inspector-II Exam

There are a number of distinctions of our Fire-Inspector-II exam questions that make it superior to those offered in the market, You can take the International Code Council Fire-Inspector-II training materials and pass it without any difficulty.

Therefore, users can pass Fire-Inspector-II exams with very little learning time.

Report this page